ALP/T20 Series - Board Mounting or Solder Tag Terminations

Related documents
IEC 384-4
DIN 41238
BS CECC 30301-033

Temperature range
Storage -55°C to +85°C
Operating -40°C t0 +85°C
Environmental classification 40/085/56

Surge voltage
1000 surges (30 seconds) at 85°C with surge voltage applied. Click here for more details.

Charge/discharge
10,000,000 cycles at 25°C and rated voltage. One cycle per second with a time constant of 0.1.

DC leakage current
After application of rated d.c. voltage for 5 minutes at 20°C, the d.c. leakage current shall not exceed (0.006 CR UR + 4) µA. Where CR is the rated capacitance in µF and UR is the rated d.c. voltage.

Vibration
10Hz to 500Hz at 0.75mm or 10g for 3 x 2hrs duration.

Insulation resistance
=> 100MW at 100V d.c., across the insulating sleeve.

Voltage proof
=> 2500V d.c., across the insulating sleeve.

Ripple current
The following values are approximate only, to give an indication of the effects of frequency and temperature on ripple current. More accurate data can be obtained by referring to the Application Notes.

FREQUENCY CORRECTION
Capacitors shall withstand the rated r.m.s. ripple current as given in the table at upper category temperature in circulating air. For frequencies other than those shown in the tables, the following multipliers should be applied to the 100Hz ripple current:

FREQUENCY (Hz)
RATED VOLTAGE D.C. 50 100 500 1k => 10k
0 - 25 0.89 1.0 1.05 1.06 1.07
40 - 160 0.81 1.0 1.28 1.33 1.39
200 - 450 0.75 1.0 1.54 1.70 1.89

TEMPERATURE CORRECTION
For ambient temperature other than 85°C the following correction factors should be employed.

AMBIENT TEMPERATURE FACTOR
30°C 2.5
50°C 2.1
70°C 1.6
85°C 1.0

N.B. The sum of the d.c. and a.c. voltage components should not exceed the d.c. voltage rating.

Life expectancy
At rated temperature with rated voltage and ripple current applied.

CAN DIAMETER (mm) LIFE EXPECTANCY (hours)
25 12000
30 15000
35 18000
40 26000

Capacitor marking
The capacitors are marked with items 1 to 7 from the following list as a minimum, and as much of the remaining information as is practical.

1 - Rated capacitance in µF
2 - Rated voltage d.c.
3 - Polarity of terminations
4 - Tolerance on rated capacitance
5 - Date code/Batch code
6 - BHC part number